1-4 Service Manual
7525-63x
Operating modes
Data streams
Mode Description
Normal Factory default
Quiet Designed for customers where noise levels are a very important
factor.
• Print quality is maintained at factory default level.
• Speed is reduced.
Eco-Mode (Off is
default):
Designed for customers where the environment is a key factor.
There are three options; Energy, Paper, and Energy/Paper.
Paper:
• Duplex is on if Energy/Paper or Paper is selected (duplex
models only) (can be overwritten by the driver).
Energy:
• Print quality is maintained.
• Power Saver is set to one minute.
• Fuser standby is off.
• The operator panel back light is off.
• Power supply energy consumption is reduced.
Energy + Paper:
*Settings associated with Energy mode plus duplex are
enabled.
Data streams
Lexmark
X548
PCL 6 emulation
✔
PostScript Level III emulation
Version 3011 of the Adobe
definition of PostScript 3 is
supported.
✔
PDF
Supports version 1.6
✔
PPDS
By default, the PPDS interpreter
is inactive. A user can activate
the data stream by PJL or by the
PPDS Emulation setting in the
Configuration Menu.
✔
PictBridge
✔
Directimage
Devices that support Directimage
support all of the following
graphics formats: TIFF, TIF,
JPEG, JPG, GIF, PNG, BMP,
PCX, and DCX.
✔
✔—Supported
✘—Not supported