Diagnostic information 2-21
7525-63x
Go Back
Previous
Next
950.xx Service
NVRAM Failure
There is a mismatch between controller
EEPROM and mirror.
950.00 through 950.29 codes—
Mismatch between controller and
mirror.
950.30 through 950.60 codes—
Mismatch between secure and
controller.
Go to “950.xx NVRAM failure service
check” on page 2-32.
951.xx Service
NVRAM Failure
Mismatch between controller EEPROM
and mirror.
951.00 through 951.29 codes—
Mismatch between controller and
mirror.
951.30 through 951.60—Mismatch
between secure and controller.
952.xx Service
NVRAM Failure
A recoverable MVRAM Cyclic
Redundancy Check (CRC) error
occurred. “n” is the offset at which the
error occurred.
Performing a POR will clear this error.
953.xx Service
NVRAM Failure
NVRAM chip failure with mirror.
954.xx Service
NVRAM Failure
The NVRAM chip failure with controller
part.
955.xx Service
Code CRC <loc>
The Code ROM or NAND flash failed
the Cyclic Redundancy Check (CRC)
check or the NAND experienced an
uncorrectible multi-bit failure. “<loc>”
indicates the source of the failure and
has one of the following values:
CRC Failure: The source is a
failing package indicated by Pn
where “n” is the package number.
This error could occur on a
controller with ROM or NAND flash
and could occur as a result of the
CRC check done when the
machine is powered on. The range
of package numbers is from 0 to
15.
Error Correction Code (ECC)
Failure: The source is a failing
page indicated by Bn where “n” is
the page number. This error occurs
only if a multi-bit failure is detected
during the ECC execution. Single
bit failures will be corrected
automatically and will not result in a
service error. The range of page
numbers is from 0 to 1023.
956.00 Service
RIP board
RIP board failure. Processor failure. Replace the RIP board. Go to “RIP board
removal” on page 4-19.
956.01 Service
RIP board
Processor over temperature.
957.xx Service
RIP board
RIP board failure. ASIC failure.
Service error messages
Error code Description Action

Table of Contents

Other manuals for Lexmark X548 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lexmark X548 Series and is the answer not in the manual?

Lexmark X548 Series Specifications

General IconGeneral
BrandLexmark
ModelX548 Series
CategoryAll in One Printer
LanguageEnglish

Related product manuals