Gocator Line Profile Sensors: User Manual
Gocator Web Interface 143
You are not required to assign a sensor to every corner.
For details on alignment targets, see Alignment Targets on page 28.
4. Click the Align button.
The sensors will start, and the alignment process will take place. Alignment is performed
simultaneously for all sensors. If the sensors do not align, check and adjust the exposure settings (page
129).
Alignment uses the exposure defined for single exposure mode, regardless of the
current exposure mode.
5. Inspect alignment results.
Data points from all sensors should now be aligned to the alignment target surface. The base of the
alignment target (or target surface) provides the origin for the system Z axis.
To perform moving alignment:
1. Do one of the following if you have not already done so.
l If the system uses an encoder, configure encoder resolution. See Encoder Resolution on page 106
for more information.
l If the system does not use an encoder, configure travel speed. See Travel Speed on page 106 for
more information.