Electra Elite IPK II Document Revision 1
Electra Elite IPK II Programming Manual 2 - 9
For BRI PKG Setup
ISDN Line Number 01~08
Item
No
Item Input Data Default
01
--- Not Used ---
02
Logical Port Number
The starting port number of a BRI
line is displayed. Two logic ports are
automatically assigned to a BRI line.
0 = Net Set
1 = For T-Bus (1~200)
2 = For S-Bus (1~256)
0
03
Connection Type
0 = Point-to-Multipoint (not
available for Networking)
1 = Point-to-Point
0
04
Layer 3 Timer Type
Each timer value of Layer 3 are set
up for every type using
Program 81-06 (T-Bus)
1~5
1
05
CLIP Information Announcement
Based on this setting, the system will
include a “Presentation Allowed” (1) or
“Presentation Restricted” (0) in the
Setup message to allow or deny the
Calling Party Number. Program
15-01-04 must also be set to a ‘1’ if this
option is enabled.
0 = Disable
1=Enable
1
06
--- Not Used ---
07
--- Not Used ---
08
Dial Sending Mode
0 = Enblock Sending
1 = Overlap Sending
1
09
Dial Information Element
(Only when Dialing Sending Mode (10-
03-08) is set for 1 (Overlap Sending)
0 = Keypad Facility
1 = Called Party Number
10
--- Not Used ---
11
--- Not Used ---
12
--- Not Used ---
13
--- Not Used ---
14
--- Not Used ---