Document Revision 1 Electra Elite IPK II
2 - 10 Program 10 : System Configuration Setup
For PRI PKG Setup
ISDN Line Number 01~24
Item
No.
Item Input Data Default
01
--- Not Used ---
02
Logical Port Number
The start port number of a PRI line is
displayed. 24 logic ports are
automatically assigned to a PRI line.
1 = for T-Bus 1~200
1
03
--- Not Used ---
04
Layer 3 Timer Type
Each timer value of Layer 3 is set up
for each type in
Program 81-06 (T-Bus)
1~5
1
05
CLIP Information
Based on this setting, the system
will include a “Presentation Allowed”
(1) or “Presentation Restricted” (0)
in the Setup message to allow or
deny the Calling Party Number.
Program 15-01-04 must also be set
to a ‘1’ if this option is enabled.
0 = Disable
1 = Enable
1
06
Length of Cable
0 = 0 ~ 40m
1 = 41~ 80m
2 = 81~ 121m
3 = 122 ~ 162m
4 = 163 ~ 200m
0
07
--- Not Used ---
08
Dial Sending Mode
0 = Enblock Sending
1 = Overlap Sending
1
09
Dial Information Element
(Only when Dialing Sending Mode
(10-03-08) is set for 1 (Overlap
Sending)
0 = Keypad Facility
1 = Called Party Number
10
--- Not Used ---
11
--- Not Used ---
12
Short / Long-Haul
0 = Short-Haul
1 = Long-Haul
0