Electra Elite IPK II Document Revision 1
Electra Elite IPK II Programming Manual 2 - 11
For DTI (T1) PKG Setup
13
Loss-Of-Signal Detection Limit
In Short-Haul Mode:
0=0.91V
1=0.74V
2=0.59V
3=0.42V
4=0.32V
5=0.21V
6=0.16V
7=0.10V
In Long-Haul Mode:
0=1.70V
1=0.84V
2=0.84V
3=0.45V
4=0.45V
5=0.20V
6=0.10V
7 = Not Defined
0
14
--- Not Used ---
Physical Port Number 01~24
Item
No.
Item Input Data Default
01
Logical Port Number
The start port number of a T1 line is
displayed. 24 logic ports are
automatically assigned to a DTI (T1)
line.
0~200 0
02
T1 Signal Format Selection
0 = D4 (12 Multi Frame)
1 = ESF (24 Multi Frame)
1
03
Clear Channel Selection
0
04
Line Length Selection
0 = 0 feet ~ 133 feet
1 = 134 feet ~ 266 feet
2 = 267 feet ~ 399 feet
3 = 400 feet ~ 533 feet
4 = 534 feet ~ 655 feet
0
Item
No.
Item Input Data Default