Maintenance
6-7
Part 1123087_02
3/2014 Nordson Corporation
5. See Figure 6‐4. Use an 8‐mm hex wrench or an adjustable wrench to
loosen (counterclockwise) and then remove the filter, taking care to keep
adhesive from dripping onto the assembly.
Figure 6‐4 Removing the adhesive filter
To install the adhesive filter
1. Confirm that the O‐ring on the new filter is in good condition.
2. Thread the filter into the manifold and then tighten the filter to 4.5 Nm
(40in.‐lb).
3. Open the shutoff valve.
4. Reinstall the hydraulics cover and restore the system to normal
operation.