Repair
8-24
Part 1123087_02
î 3/2014 Nordson Corporation
To install the pneumatic control assembly
1. Connect the air lines to ports 1 and 2 on the replacement pneumatic
control assembly as shown Figure 8â15.
2. Connect the power cable to the pneumatic assembly.
3. Secure the pneumatic assembly and exhaust plenum to the melter
chassis using the screws removed previously.
WARNING! Risk of personal injury. Do not operate the system without a
properly installed cyclone exhaust filter and filter cover.
4. Reinstall the cyclone exhaust filter and cover.
5. Reinstall the hydraulics cover and restore the system to normal
operation.