Repair
8-23
Part 1123087_02
3/2014 Nordson Corporation
2. See Figure 8‐15. Disconnect the power cable from the pneumatic control
assembly (3).
3. Disconnect the air lines (1, 2) from the pneumatic control assembly and
carefully remove the assembly. Leave the exhaust plenum connected to
the flexible exhaust hose.
1
2
3
Figure 8‐15 Replacing the pneumatic control assembly (port numbers enlarged for
clarity)
1. Blue air line connected to port 1
2. Yellow air line connected to port 2
3. Pneumatic control assembly