P/N 1121629
Installation
3-30
Part 1123087_02
3/2014 Nordson Corporation
Connect Applicator Signal Wiring (contd)
See Figure 3‐23.
2. Route customer‐supplied signal wiring from the applicator solenoid valve
through the SL‐16 strain relief(2) on the bottom of the melter.
NOTE: To achieve the best electrical noise immunity in an industrial
environment, Nordson Corporation recommends shielded, twisted wire.
NOTE: A solenoid valve‐to‐hose interface board cable is available. Refer
to Optional Accessories in Section 9, Parts.
3. Connect each pair of solenoid valve wires to the appropriate channel
output terminals on connector P/N 1121629 from the ship-with kit.
NOTE: The X1 terminals are polarized.
4. Plug the connector into terminal block X1 (1) on the hose interface
board(3).
5. If a ground lead is used, connect it to a chassis terminal on X1.