PROCEDURE NO: PR470047 REVISION 3
Page 4 of 4
B) Apply Sika 252.
C) Position and glue side panels with reference to
the lines draw at step 1.15b) (make sure
tolerance of ±1.5mm is met). Compress side
panel using a blackboard eraser.
Note: Position side panel before compressing
double-face tape..
D) If applicable, remove excess of Sika and clean
surfaces using Sika 208.
Section view
A) Position entrance door and service door frame
vertical molding.
1.30
B)
Drill using a #30 drill bit & rivet.
Section 2 Replacement/Repair
Panel removal. See la PR000001, Section 2. 2.00