Chapter 9 Running Your Library
Restarting the Library
Scalar i500 User’s Guide 243
The paths to open the appropriate screens are as follows:
• From the Web client, select
Operations > System Shutdown.
• From the operator panel, select
Operations > Shutdown.
Restarting the Library
The Restart command shuts down and restarts the library’s operating
system and firmware. When performing a restart, the library finishes the
current command, then shuts down the library and restarts it. During the
restart, the library brings all tape drives and partitions online and
performs an inventory of cartridges, tape drives, and slots.
Before performing a restart, make sure the connected host applications
are not sending commands to the library.
Restarting takes approximately 5 minutes for the control module and
longer for the 14U and higher library configurations.
If the “Not Initialized” message appears on the operator panel after the
restart process is complete, the library did not properly initialize. View
the
All RAS Tickets screen to find the problem that is preventing the
library from properly initializing. See Viewing
RAS Tickets on page 488.
The paths to open the appropriate screens are as follows:
• From the Web client, select
Operations > System Shutdown.
• From the operator panel, select
Operations > Shutdown.
Logging In
All users, service users, and administrators must log in to the library to
perform library functions or view library operations.