EasyManua.ls Logo

Quantum Scalar i500

Quantum Scalar i500
575 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Scalar i500 User’s Guide 545
55 Loading or
threading
failure
C The operation has failed because the
media cannot be loaded and threaded:
1. Remove the cartridge, inspect it as
specified in the product manual, and
retry the operation.
2. If the problem persists, call the tape
drive supplier help line.
The drive is unable to
load the media and
thread the tape.
56 Unrecoverable
unload failure
C The operation has failed because the
medium cannot be unloaded:
1. Do not attempt to extract the tape
cartridge.
2. Call the tape driver supplier help line.
The drive is unable to
unload the medium.
57 Automation
interface failure
C The tape drive has a problem with the
automation interface:
1. Check the power to the automation
system.
2. Check the cables and cable
connections.
3. Call the supplier help line if problem
persists.
The drive has
identified an
interface fault.
58 Microcode
failure
W The tape drive has reset itself due to a
detected microcode fault. If problem
persists, call the supplier help line.
Microcode bug.
59 WORM
medium —
integrity check
failed
W The tape drive has detected an
inconsistency during the WORM
medium integrity checks. Someone may
have tampered with the cartridge.
Someone has
tampered with the
WORM medium.
No. Flag Severity
Recommended Application Client
Message Probable Cause

Table of Contents