Chapter 3 Configuring Your Library
Using the Setup Wizard
Scalar i500 User’s Guide 56
If you are using IPv6: On the Setup Wizard: Enable IPv6 screen,
select the
Enable IPv6 check box and click Next. You have enabled
IPv6 but you will not be prompted to configure IPv6 settings
here. Continue with the Setup Wizard screens. Then, when you
are finished using the Setup Wizard, configure the IPv6 network
settings by going to
Setup > Network Mgmt on the operator panel.
4 Log out of the operator panel.
5 Using the default administrator account, log in to the Web client.
Type
admin in the User Name text box and password in the Password
text box.
6 Complete the
Setup Wizard screens on the Web client interface. The
final
Setup Wizard screen will prompt you to apply your settings.
When you have completed the
Setup Wizard, the Library
Configuration report appears on the Web client. The Library
Configuration report provides information on the library’s tape
drives, partitions, I/E stations, storage slots, cleaning slots, and
loaded media. See Viewing the Library Configuration Report
on
page 272 for more information on the Library Configuration report.
Details on using the Setup Wizard include:
The only time that you do not need to log in to the library is when the
Setup Wizard appears on the operator panel the first time the library
is powered on.
After a timeout period of one hour, the Setup Wizard will close, and
you will be logged out of the library. Use the default administrator
account to log in to the operator panel.
If you time out of the Setup Wizard or do not complete all the Setup
Wizard screens, the library will apply the default configuration
settings plus whatever modifications you made (see Default
Configuration Settings on page 57).
You cannot log in to the library from the Web client until you have
configured network settings on the operator panel. To change IPv4
settings and configure IPv6 settings, go to
Setup > Network Mgmt.
Note: Depending on the size of the library, there may be a slight
delay after you apply the settings in the Setup Wizard
while the Library Configuration report page loads.

Table of Contents

Other manuals for Quantum Scalar i500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantum Scalar i500 and is the answer not in the manual?

Quantum Scalar i500 Specifications

General IconGeneral
BrandQuantum
ModelScalar i500
CategoryStorage
LanguageEnglish

Related product manuals