Spectrum Measurements
R&S
®
ESR
223User Manual 1175.7068.02 ─ 12
Ch Power ACLR..........................................................................................................223
C/N, C/No (span > 0)...................................................................................................223
OBW (span > 0).......................................................................................................... 223
Spectrum Emission Mask............................................................................................223
Spurious Emissions.....................................................................................................224
Time Domain Power (zero span).................................................................................224
All Functions Off..........................................................................................................224
APD.............................................................................................................................224
CCDF.......................................................................................................................... 224
TOI.............................................................................................................................. 224
AM Mod Depth............................................................................................................ 224
Harmonic Distortion.....................................................................................................225
All Functions Off..........................................................................................................225
Ch Power ACLR
Activates the active channel or adjacent-channel power measurement either for a sin-
gle carrier signal or for several carrier signals, depending on the current measurement
configuration, and opens a submenu to configure the channel power measurement.
For details see Chapter 6.1.1.2, "Measuring Channel Power and Adjacent-Channel
Power", on page 225.
Remote command:
CALCulate<n>:MARKer<m>:FUNCtion:POWer:SELect on page 720
CALCulate<n>:MARKer<m>:FUNCtion:POWer:RESult? on page 721
CALCulate<n>:MARKer<m>:FUNCtion:POWer[:STATe] on page 724
C/N, C/No (span > 0)
Opens a submenu to configure the carrier/noise ratio measurement. Measurements
without (C/N) and measurements with reference to the bandwidth (C/No) are possible.
For details see Chapter 6.1.1.3, "Measuring the Carrier-to-Noise Ratio", on page 249.
OBW (span > 0)
Activates measurement of the occupied bandwidth according to the current configura-
tion and opens a submenu to configure the measurement. For details see Chap-
ter 6.1.1.4, "Measuring the Occupied Bandwidth", on page 252.
Remote command:
CALCulate<n>:MARKer<m>:FUNCtion:POWer:SELect on page 720
CALCulate<n>:MARKer<m>:FUNCtion:POWer:RESult? on page 721
CALCulate<n>:MARKer<m>:FUNCtion:POWer[:STATe] on page 724
Spectrum Emission Mask
Opens a submenu to configure the Spectrum Emission Mask measurement.
The Spectrum Emission Mask (SEM) measurement defines a measurement that moni-
tors compliance with a spectral mask.
For details see Chapter 6.1.1.5, "Measuring with Spectrum Emission Masks",
on page 256.
Remote command:
SENS:SWE:MODE ESP, see [SENSe:]SWEep:MODE on page 761