Spectrum Measurements
R&S
®
ESR
236User Manual 1175.7068.02 ─ 12
Chan Pwr/Hz.......................................................................................242
Power Mode........................................................................................242
Clear/Write................................................................................242
Max Hold.................................................................................. 243
Select Trace........................................................................................243
ACLR (Abs/Rel).................................................................................. 243
Adjust Settings....................................................................................243
Sweep Time.................................................................................................. 243
Fast ACLR (On/Off)...................................................................................... 244
Set CP Reference.........................................................................................244
User Standard...............................................................................................244
Load....................................................................................................245
Save....................................................................................................245
Delete................................................................................................. 245
Noise Correction........................................................................................... 245
Adjust Ref Lvl................................................................................................246
Ch Power ACLR
Activates the active channel or adjacent-channel power measurement either for a sin-
gle carrier signal or for several carrier signals, depending on the current measurement
configuration, and opens a submenu to configure the channel power measurement.
With default settings the measurement is performed by integrating the powers at the
display points within the specified channels (IBW method).
If several TX cahnnels (carriers) are activated, the number of measured values is
increased to ensure that adjacent-channel powers are measured with adequate accu-
racy.
For general information on performing channel or adjacent-channel power measure-
ments, see Chapter 6.1.1.2, "Measuring Channel Power and Adjacent-Channel
Power", on page 225.
Remote command:
CALCulate<n>:MARKer<m>:FUNCtion:POWer:SELect on page 720
CALCulate<n>:MARKer<m>:FUNCtion:POWer:RESult? on page 721
CALCulate<n>:MARKer<m>:FUNCtion:POWer[:STATe] on page 724
CP/ACLR Standard ← Ch Power ACLR
Opens an edit dialog box to select the settings according to predefined standards. For
details on the available standards see "Predefined CP/ACLR Standards" on page 246.
By default no standard is set.
The selection of the standard influences the following parameters (see "Optimized Set-
tings for CP/ACLR Test Parameters" on page 247):
channel spacing and adjacent-channel spacing
channel bandwidth, adjacent-channel bandwidth, and type of filtering
resolution bandwidth
video bandwidth
detector
# of adjacent channels
trace averaging (switched off)
Measurements

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the R&S ESR Series and is the answer not in the manual?

R&S ESR Series Specifications

General IconGeneral
BrandR&S
ModelESR Series
CategoryReceiver
LanguageEnglish

Related product manuals