272 Rockwell Automation Publication 2198-UM002L-EN-P - October 2021
Chapter 7 Troubleshoot the Kinetix 5700 Drive System
Table 149 - Drive Behavior, FLT Sxx Fault Codes
Exception Fault Code Exception Text
Inverter
Modules
2198-xxxx
Permanent
Magnet
Motor
Induction
Motor
Fault Action
Best Available
Stopping Action
(applies to major faults)
Ignore
Alarm
Minor Fault
Major Fault
FLT S02 – MTR COMMUTATION Motor Commutation Fault -ERSx X – –––XDisable/Coast
FLT S03 – MTR OVERSPEED FL Motor Overspeed Factory Limit Fault -ERSx X X –––XDisable/Coast
FLT S04 – MTR OVERSPEED UL Motor Overspeed User Limit Fault
-ERS3 (series A)
XXXXXX
Decel/Hold
-ERS4
-ERS3 (series B)
Ramped Decel
(1)
/Hold
FLT S05 – MTR OVERTEMP FL
Motor Overtemperature Factory Limit Fault -ERS3 (series A)
X
– ––––Disable/Coast
Motor Overtemperature Factory Limit Fault
(If #589 vertical load control)
-ERS4
-ERS3 (series B)
X
– – – – Current Decel/Disable
Motor Overtemperature Factory Limit Fault
(If not #589 vertical load control)
––––Disable/Coast
FLT S07 – MTR OVERLOAD FL Motor Thermal Overload Factory Limit Fault
-ERS3 (series A)
XX
–––
X
Decel/Disable
-ERS4
-ERS3 (series B)
–––
Ramped Decel
(1)
/Disable
FLT S08 – MTR OVERLOAD UL Motor Thermal OverLoad User Limit Fault
-ERS3 (series A)
XXXXXX
Decel/Hold
-ERS4
-ERS3 (series B)
Ramped Decel
(1)
/Hold
FLT S09 – MTR PHASE LOSS Motor Phase Loss -ERSx X–XXXXDisable/Coast
FLT S10 – INV OVERCURRENT Inverter Overcurrent Fault -ERSx X X –––XDisable/Coast
FLT S11 – INV OVERTEMP FL
Inverter Overtemperature Factory Limit
Fault
-ERS3 (series A)
XX
–––
X
Disable/Coast
Inverter Overtemperature Factory Limit
Fault
(If #589 vertical load control)
-ERS4
-ERS3 (series B)
– – – Current Decel/Disable
Inverter Overtemperature Factory Limit
Fault
(If not #589 vertical load control)
––– Disable/Coast
FLT S13 – INV OVERLOAD FL
Inverter Thermal Overload Factory Limit
Fault
-ERS3 (series A)
XX
–––
X
Disable/Coast
-ERS4
-ERS3 (series B)
– – – Current Decel/Disable
FLT S14 – INV OVERLOAD UL Inverter Thermal Overload User Limit Fault
-ERS3 (series A)
XXXXXX
Decel/Hold
-ERS4
-ERS3 (series B)
Ramped Decel
(1)
/Hold
FLT S16 – GROUND CURRENT Ground Current Factory Limit Fault
-ERSx
Single-axis
inverters
X X –––XDisable/Coast
FLT S22 – AC POWER LOSS Converter AC Power Loss Fault
-ERS3 (series A)
XXXXXX
Decel/Disable
-ERS4
-ERS3 (series B)
Ramped Decel
(1)
/Disable
FLT S27 – BUS REG OVERTEMP FL
(2)
Bus Regulator Overtemperature Factory
Limit Fault
-ERSx X X –––XDisable/Coast
FLT S32 – BUS CAPACITOR MODULE
FAILURE
Bus Capacitor Module Failure
-ERS3 (series A)
XXXXXX
Decel/Hold
-ERS4
-ERS3 (series B)
Ramped Decel
(1)
/Hold
FLT S33 – BUS UNDERVOLT FL Bus Undervoltage Factory Limit Fault
-ERS3 (series A)X X –––XDisable/Coast
-ERS4
-ERS3 (series B)
X X –––X
Disable/Coast
(3)
FLT S34 – BUS UNDERVOLT UL Bus Undervoltage User Limit Fault
-ERS3 (series A)
XXXXXX
Decel/Hold
-ERS4
-ERS3 (series B)
Ramped Decel
(1)
/Hold
FLT S35 – BUS OVERVOLT FL Bus Overvoltage Factory Limit Fault -ERSx X X –––XDisable/Coast
FLT S37 – BUS POWER LOSS Bus Power Loss
-ERS3 (series A)
XXXXXX
Decel/Disable
-ERS4
-ERS3 (series B)
Ramped Decel
(1)
/Disable
FLT S38 – FUSE BLOWN Bus Power Fuse Blown Fault -ERSx X X –––XDisable/Coast
FLT S40 – BUS POWER SHARING FAULT Bus Power Sharing Fault
-ERS3 (series A)
XXXXXX
Decel/Disable
-ERS4
-ERS3 (series B)
Ramped Decel
(1)
/Disable
FLT S41 – MTR AQB STATE FL
Feedback Signal Noise FL -ERSx X X –––XDisable/Coast
FLT S43 – FDBK LOSS FL
(4)
(6)
Feedback Signal Loss FL -ERSx X X –––XDisable/Coast