DMG 3200/3100/3000User Manual
Page 130 (306)
Figure 7.12- Delivery Descriptors for Cable
Figure 7.13 - Delivery Descriptors for Satellite
Figure 7.14- Delivery Descriptors for Terrestrial
7.3.1.2 Import TS PID
Checking the Import TS PIDs on the Transport tab allows you to define PIDs to be manually
added to the output transport stream. These PIDs will not be signalled in the PSI/SI. Click + to
add additional PIDs and - to remove them.
Figure 7.15 - Import TS PIDs
Slot
Contains a selection of the available input modules
Input
Contains a selection of the enabled input ports on the corresponding slot.
PID
Input PID to be forwarded
Out PID
The input PID is mapped to this output PID number; each output PID
occupies one channel through the output module like any other channel.
The maximum number of channels through the output module is 250.
Manually mapped PIDs on outgoing Transport Streams are not checked for
PID conflicts. These PIDs are not signaled in the generated PSI/SI table.
Importing PIDs is treated as a service by the system consequently reducing the
number of services handled by the module with one.