10.3.2.3 Mute on Error
Mute on Error is a form of output redundancy, apart from OSPF, where the output is disabled if
there is an error with the input stream. This feature can be used in situations where the
equipment receiving the signals require an incoming bitrate of zero (no bitrate), so that a switch
to a backup service or input can take place.
To enable or disable Mute on Error, use the check box in the Edit Redundancy Options dialog
.This feature must also be enabled or disabled for each port on the IP output settings.
The Mute on Error functionality does not require the ‘Output Redundancy’ license.
Enabling Output Redundancy on ASI-Cloned output module and ASI output
modules enables Mute on Error by default.