10.4.1 Redundancy Group Configuration
The redundancy group parameters are defined under the Card->Groups navigation pane.
To edit the group settings press the edit to the right of the group name.
Following parameters are present under Group setting.
Name
Automatically generated based on card type
Switch mode
Select a suitable mode for each redundancy pair. The
following modes are available:
Off Stop switching whether it is on main or backup
Floating Switch when an alarm is set on the service that is
active, ignore clear alarms
Reverting Switch to backup only if there is an alarm on main
but not on backup; switch back when alarms on main are
removed or set on backup (this is the recommended mode).
Switch delay
A delay added when the switch module receives an alarm
Switch back delay
Specify the Switch back delay.
Switch
Select from a list of previously defined switches.
10.4.2 Redundancy Module Configuration
Within the group, the role of each card and for encoder modules, its cabling info must be
defined. To edit the group press the edit to the right of the card.