DMG 3200/3100/3000User Manual
Page 54 (306)
aac_adts
e-ac3-e
Language
The language signaled on the input. If this is not a filtering criteria then use
wildcard “*”
Override
The new language descriptor to be used for the incoming component.
Note
If several PIDs are matching the input filtering criteria’s, then the signaling for all
these components will be updated.
If the input signaling is dual mono, and no Language (source) is specified, then the
right channel descriptor will be replaced.
5.3.5 Edit options on existing manual PSI
Under the Manual-PSI node all current manual PSI rules will be listed. Not all rules can be
changed once they are defined. These are indicated with a blue circle with the “?” mark. To
change these components they need to be removed and re-added. The rules indicated with a
pencil can be changed without remove / add operation.