9.2 Electronic Program Guide (EPG)
The Electronic Program Guide (EPG) module is responsible for collecting event information
from all incoming transport streams, usually via PID 18, and regenerating this information for
EPG-enabled outgoing networks.
Figure -9.3 - EPG Node
The EPG node has three sub-nodes:
Status the Status node displays the EPG status for all outgoing transport streams
aggregated according to each network.
Source the Source node displays
Setup Configure matching criteria for incoming EIT tables, manually defining EIT PIDs,
EPG synchronisation and other miscellaneous parameters
9.2.1 EPG Status
The EPG Status node (Figure 9.4) displays all outgoing transport streams carrying EPG data.
The data is aggregated according to each network service configuration.