EasyManua.ls Logo

Sencore DMG 3200 - Page 282

Sencore DMG 3200
306 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DMG 3200/3100/3000 – User Manual
Page 282 (306)
Figure 10.34 – MMI Redundancy settings-MAIN MMI
Following are MMI Redundancy Settings parameters:
Enable
This is the checkbox to enable/disable MMI Redundancy.
Enabling means both auto config database synchronization and
auto backplane switching for all cards when they lose contact
with MMI.
MMI Redundancy mode Either of one: Once or Reverting.
Switch delay
This is the delay before a module switches backplane when
MMI switch has been triggered. It is not applied when Manual
Switch is performed.
Switch back delay
This delay is until now only applied on Reverting mode, working
right now only for Alarms trigger.