Step by step
General settings
120
Without MSN verification
Remote Administration will be performed without veri-
fying the Service MSN transmitted.
Required: Programming mode must be activated (*95
31994).
dkd w Enter the programming code.
q or r w Activate/Disable:
q = Activated
r = Deactivated (default)
w Initial status for programming mode.
Remote administration via dtmf
With this feature you can configure the HiPath 1100 re-
motely with an MF telephone.
Required: Programming mode must be activated (*95
31994).
eik w Enter the programming code.
q or r Activate/deactivate remote configuration:
q = Activate remote configuration (default)
r = Disable remote configuration (default)
w Initial status for programming mode.
t Replace the handset.
Example: Remote configuration must be activated and
the programming extension must have a conversation
in progress on the external line over which program-
ming is to be performed.
qmme w With a conversation in progress enter the programming
extension code to transfer control of the HiPath 1100 to
the remote programmer.
p w The remote programmer must now enter the system
password using an MF telephone (default - 31994).
w Wait for a confirmation tone to indicate that the pass-
word was accepted.