Step by step
Digital trunk settings
156
ISDN Layer 2
Allows you to change certain default ISDN settings for
specified countries.
Required: Programming mode must be activated (*95
31994).
edf w Enter the programming code.
de, df, Enter the S
0
module slot on the system
1
.
dg or ee
p
Enter the slot for the S
0
module slot:
dd . de = For the HiPath 1120 (The slot for
port 00 is only used for the external line - PP or PMP)
dd . dh = For the HiPath 1150;
dd . dh = For theHiPath 1190 (For the second
module, place position 11 and port from 00 ... 04).
q or r w Activate/deactivate layer
q = Activated
r = Deactivated
w Initial status for programming mode.
B Channel
Allows you to change some default ISDN settings for
specified countries.
Required: Programming mode must be activated (*95
31994).
edg w Enter the programming code.
p Enter the S
0
module slot on the system.
df = For the HiPath 1120
dg = For the HiPath 1150
de and ee = For the HiPath 1190 .
p Enter the slot for the S
0
module slot:
dd . de = For theHiPath 1120 (The slot for
port 00 is only used for the external line - PP or PMP)
[1] Module slots are: HiPath 1120 (02), HiPath 1150 (03) and HiPath
1190 (01 and 11).