External line settings
51
Step by step
d.m
or dd . mm Enter the external access code for the main PABX (one
or two digits) and wait for a confirmation tone:
d. m = second external access code, one
digit
dd .mm = second external code, two digits
Wait 5 seconds w Wait for a confirmation tone.
Initial status for programming mode.
False tone
This sends an external line dial tone even when there is
no external line available. This feature only works for MF
extensions.
Required: Programming mode must be activated (*95
31994).
djg w Enter the programming code.
q or r w Activate/Disable a false tone:
r = Deactivated for Argentina, Korea and India
q = Activated for all other countries (default)
w Initial status for programming mode.
Internal access code for automatic
seizure
This features specifies the code to be used for making
internal calls when an extension is configured for auto-
matic seizure of an external line.
Access codes are configured according to the country.
If no access code is specified, the feature will not work.
If no value is entered, a confirmation tone will
not be checked after the line is occupied.
If LCR (configured via the HiPath 1100 Manager)
or Emergency numbers is activated, the user will
hear a false tone.