Step by step
EVM module
168
• Mailboxes can be configured automatically or by the
user.
• Capability for message/music playback before an-
swering.
• Up to two different greetings.
• Manual or day/night service greeting selection.
• Context-sensitive user’s guide
• Messages inform users of current menu options.
• Two parallel actions are allowed for call transfer and
auto-answering (2 message ports).
• Capability for up to 120 minutes of voice recording.
• Maximum voice message recording time for each
mailbox is 5 minutes, configurable from 1 to 5 min-
utes. The default setting is 2 minutes.
• Date and time display for each message.
• Memory overload alert when it exceeds 80%.
Duration of greeting messages
This setting determines a time period within which the
caller can record a greeting message.
Required: Programming mode must be activated (*95
31994).
fdd w Enter the programming code.
de ... di Enter the time available for the caller to record a mes-
sage (1 to 5 minutes). The default setting is 2 minutes.
w Initial status for programming mode.
When a call to an extension is forwarded to an
EVM mailbox (call forward no answer or busy) a
message is played, explaining why the call is be-
ing forwarded.
These messages are played before the greeting
message and cannot be overwritten.
Messages:
• Call forwarding - Busy after call forwarding no
answer: "User’s connection is
busy at the moment".
• Call forward no answer: "The
user you are calling is not answering."