EasyManua.ls Logo

Siemens HiPath 1120 - External Line Call Direction; Flash Duration on Analog Line

Siemens HiPath 1120
241 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
External line settings
45
Step by step
External line call direction
When a user tries to access a line, lines that have been
previously programmed as outgoing are given priority. If
an incoming call is received over that line, however, it
will come through as usual.
To avoid this situation, the method for accessing exter-
nal lines can be defined at the time of making or receiv-
ing a call. This facility is usually contracted with the local
carrier to ensure optimal usage of all lines available.
Required: Programming mode must be activated (*95
31994).
eii w Enter the programming code.
p w Enter a number for an external line (e.g., 801).
e.gw Enter the number for the type of access to an external
line:
e = bidirectional (default)
f = incoming unidirectional
g = outgoing unidirectional
p w Enter the next external line number.
or
r w Press this key.
Initial status for programming mode.
Flash duration on analog line
The duration of the Flash signal that is sent by the sys-
tem to each analog trunk can be configured individually.
Flash signal duration depends on the specific setting for
each country.
If the country configuration (Æ page 20) or the type of
analog trunk (Æ page 23) is changed, the Flash duration
will automatically reset to the default value.
Required: Programming mode must be activated (*95
31994).
eel w Enter the programming code.
p w Enter a number for an analog trunk (e.g., 801).
di . mm w Enter the length of time (05 to 99) for the Flash signal,
where 05 = 50 ms... 99 = 990 ms.

Table of Contents

Other manuals for Siemens HiPath 1120

Related product manuals