Step by step
Important settings
34
Special class of service for a blocked exten-
sion
This allows you to switch a blocked extension (with an
electronic lock) to any class of service.
Required: Programming mode must be activated (*95
31994).
dmj w Enter the programming code.
p w Enter the extension number (e.g. 12/102).
p w Enter the class of service for the extension with the ac-
tivated lock:
d = No trunk access (default setting for all exten-
sions)
e = Outward-restricted trunk access with Denied
List 1
(10 slots)
f = Outward-restricted trunk access with Denied
List 2
(25 slots)
g = Outward-restricted trunk access with Denied
List 3
(35 slots)
h = Outward-restricted trunk access with permis-
sion list 1
(10 slots)
i = Outward-restricted trunk access with permis-
sion list 2
(25 slots)
j = Outward-restricted trunk access with Permis-
sion list 3
(25 slots)
k = Unrestricted trunk access (default for all lines)
r w Press this key.
Initial status for programming mode.
To assign a COS to additional lines, repeat the program-
ming steps described above.