Digital trunk settings
149
Step by step
S
0
ports
This setting specifies the operating mode for the S
0
module, maximizing the system’s port usage.
This option is best for the HiPath 1190 due to its high
port capacity. The goal is to obtain the greatest possible
extension numbers/external lines allowed according to
the following port detection rules:
External line and extension (default): Each port will
decrease the number of external line slots by 2 and
extension slots by 1. The connection may be PP,
PMP or S
0
Bus line (see item "Operation Mode for
S0 Line").
External line only: Each port will decrease the num-
ber of external line slots by 2. The connection must
be PP or PMP. If it has been previously configured as
S
0
Bus line, the connection will be automatically re-
versed to PP (which is the default).
Extension only: Each port will decrease the exten-
sion number slots by 1. The connection must be a S
0
Bus line. If it has been previously configured as PP
or PMP, the connection will be automatically re-
versed to S
0
Bus line.
Required: Programming mode must be activated (*95
31994).
djf w Enter the programming code.
de, df, Dial the S
0
module slot number on the system
1
.
dg or ee
e
... g Select an operating mode:
e = External line and extension (default)
f = External line only
g = Extension only
de, df, Enter the next slot for the S
0
module.
dg or ee
or
After completing the configuration, the system
must be restarted.
[1] Module slots are: HiPath 1120 (02), HiPath 1150 (03) and HiPath
1190 (01 and 11).