Fax/DID
145
Step by step
Collect call barring for Fax/DID
When this blocking is activated, the system automati-
cally rejects all incoming collect calls to a Fax/DID over
a digital line. Calls received over an analog line are re-
jected only at the moment they are answered. Call bar-
ring will not work for calls transferred to a Fax/DID.
Required: Programming mode must be activated (*95
31994).
ddl w Enter the programming code.
e ... h w Select an operating mode for the Fax/DID Module:
e = Fax
f = Attendant
g = Fax/DID
h = Greeting (message)
q or r w Activate/Deactivate collect call barring for the selected
mode:
q = Activate
r = Deactivate (default)
p w Enter the next operating mode.
or
r w Press this key.
Initial status for programming mode.
If a call has been answered at least once by the
system, collect call barring cancels the blocking.
If an incoming call over a digital line is forwarded
because there was no answered (*14), and col-
lect call barring is activated, the call will ring at
the first attendant for the external line.