Step by step
Digital trunk settings
150
r w Press this key.
Initial status for programming mode.
Operation Mode for S
0
Line
This setting specifies the type of connection between
the S
0
Module digital lines and the local carrier. The con-
nection can be Point-to-Point or Point-to-Multipoint or S
0
Bus.
Required: Programming mode must be activated (*95
31994).
emd w Enter the programming code.
de, df, Enter the S
0
module slot on the system
1
.
dg or ee .
p Enter the physical position of the port on the S
0
module
dd . de = For the HiPath 1120 (The Position of
the Port 00 is only for the external line - PP or PMP)
dd .dh = For the HiPath 1150;
dd .dh = For the HiPath 1190 (For the second
module, place position 11 and port from 00 ... 04).
e ... g w Select the type of connection for the external digital
line.
e = Point-to-Point (PP - default for the first port)
f = Point-to-Multipoint (PMP)
g = Bus S
0
line call (default for all other ports)
p Key in the physical slot of the port in the S
0
module
or
r w Press this key.
Initial status for programming mode.
[1] Module slots are: HiPath 1120 (02), HiPath 1150 (03) and HiPath
1190 (01 and 11).
With the HiPath 1120, the S
0
module’s first port
can only be a digital line, PP or PMP. It cannot be
programmed as an S
0
bus.
With other switches, the first port may also be
configured as an S
0
bus.