Important settings
39
Step by step
Connection of GSM/SIP boxes with
LCR access
GSM boxes work as if the call were sent from a GSM
cell phone and the SIP boxes work as if the call were
made using a PC. Thus the call can be sent by the
cheapest route according to the analysis of the destina-
tion of the call using the rule configured in the LCR.
It is possible to connect GSM/SIP boxes to the HiPath
1100 using the S
0
module where the ISDN lines must
be set in a line group according to the carrier type: GSM
or SIP.
Activating the time for LCR fallback
This timer should be activated for routes subject to de-
lays or problems making call connections (for example,
SIP boxes). When the preset time has elapsed, the call
is routed to the Default Carrier defined in that rule of the
LCR (See Manager - A31003-K1160-M810-*, LCR).
Required: Programming mode must be activated (*95
31994).
fid w Enter the programming code.
d or lmda lmm Enter the number for the group of external lines (e.g: 0,
890)
q or r w Activating/Disabling the timer:
q = Activated
r = Deactivated (default)
w Initial status for programming mode.
To install these peripherals, consult the manual
of the respective products and the support tech-
nician.