152 TimeProvider 2300/2700 User’s Guide 098-00564-000 Revision A3 – July, 2013
Chapter 3
TimeProvider 2300/2700 CLI Command Set
show ref
Use this command to display the configuration for reference selection including
reference selection criteria, input priorities and configured PQL values, switching
mode, and the reference status.
Command Syntax:
show ref config
show ref status
Example 1:
TP2700> show ref config
Response 1:
Reference Criteria : priority
Reference Switch Mode : AutoReturn
Time Reference Config
--------------------------------------------------
|Reference |Priority |config-PQL |use-config-pql |
|----------|---------|-----------|---------------|
|GNSS |2 |3 | enable |
|..........|.........|...........|...............|
|PTP |1 |1 | enable |
--------------------------------------------------
Frequency Reference Config
--------------------------------------------------
|Reference |Priority |config-PQL |use-config-pql |
|----------|---------|-----------|---------------|
|GNSS |2 |3 |enable |
|..........|.........|...........|...............|
|PTP |1 |1 |enable |
|..........|.........|...........|...............|
|SYNCE |4 |3 |enable |
|..........|.........|...........|...............|
|T1E1 |3 |3 |disable |
--------------------------------------------------
Example 2: