68 TimeProvider 2300/2700 User’s Guide 098-00564-000 Revision A3 – July, 2013
Chapter 3
TimeProvider 2300/2700 CLI Command Set
|137 |critical|enable |0 |"PLL synthesizer unlock" |
|....|........|.......|.......|................................................|
|138 |critical|enable |0 |"Rubidium unlock" |
|....|........|.......|.......|................................................|
|139 |event |enable |0 |"Temperature out of range" |
|....|........|.......|.......|................................................|
|151 |critical|enable |0 |"Production configuration data error" |
|....|........|.......|.......|................................................|
|152 |event |enable |0 |"Timeline has been changed" |
|....|........|.......|.......|................................................|
|153 |event |enable |0 |"Phase has been aligned" |
|....|........|.......|.......|................................................|
|154 |event |enable |0 |"System log time has been updated" |
|....|........|.......|.......|................................................|
|155 |event |enable |0 |"System reboot" |
--------------------------------------------------------------------------------
Level : User, Config and Admin
set alarm-config
Use this command to provision the alarm state, alarm level, and reporting delay time
for the specified alarms. The reporting delay time is the amount of time from when
the alarm occurred to when it is reported. The delay parameter will delay the
reporting of an alarm by the configured amount.
Command Syntax:
To provision the state of the specified alarm number:
set alarm-config state {alarm [0 to 300] | all} {enable |
disable}
To provision the level of the specified Alarm number:
set alarm-config level {alarm [0 to 300] | all}
{2 |3 | 4 | 5}
where:
Note: If an alarm condition is set and then cleared before the delay
expires, then the alarm will not be reported.