66 TimeProvider 2300/2700 User’s Guide 098-00564-000 Revision A3 – July, 2013
Chapter 3
TimeProvider 2300/2700 CLI Command Set
show alarm-config
Displays the alarm configuration including alarm ID, severity, state, reporting delay
and description for the TP 2300/2700 alarms. This also displays if the alarm is
transitory.
Command Syntax:
show alarm-config
Example:
TP2700> show alarm-config
Response :
--------------------------------------------------------------------------------
|ID |Severity|State |Delay |Event/Alarm Descriptions |
|----|--------|-------|-------|------------------------------------------------|
|1 |minor |enable |0 |"Entered time/frequency warm-up state" |
|....|........|.......|.......|................................................|
|2 |minor |enable |0 |"Entered time/frequency free-run state" |
|....|........|.......|.......|................................................|
|3 |event |enable |0 |"Entered time/frequency fast-track state" |
|....|........|.......|.......|................................................|
|4 |event |enable |0 |"Entered time/frequency normal-track state" |
|....|........|.......|.......|................................................|
|5 |event |enable |0 |"Entered time/frequency bridging state" |
|....|........|.......|.......|................................................|
|6 |minor |enable |0 |"Entered time/frequency holdover state" |
|....|........|.......|.......|................................................|
|7 |major |enable |0 |"Entered time/frequency ext holdover state" |
|....|........|.......|.......|................................................|
|8 |minor |enable |0 |"Entered time/frequency holdover rec state" |
|....|........|.......|.......|................................................|
|21 |minor |enable |0 |"GNSS/SYNCE/PTP/T1E1 input poor quality" |
|....|........|.......|.......|................................................|
|22 |event |enable |0 |"GNSS/PTP input time qualified" |
|....|........|.......|.......|................................................|
|23 |event |enable |0 |"GNSS/SYNCE/PTP/T1E1 input freq qualified" |
|....|........|.......|.......|................................................|
|24 |event |enable |0 |"GNSS/PTP input selected as time reference" |
|....|........|.......|.......|................................................|
|25 |event |enable |0 |"GNSS/SYNCE/PTP/T1E1 input sel as freq ref" |
|....|........|.......|.......|................................................|
|26 |minor |enable |0 |"T1E1 input Loss Of Signal (LOS)" |
|....|........|.......|.......|................................................|
|27 |minor |enable |0 |"T1E1 input Alarm Indication Signal (AIS)" |
|....|........|.......|.......|................................................|
|28 |minor |enable |0 |"T1E1 input Out Of Frame (OOF)" |
|....|........|.......|.......|................................................|
|29 |minor |enable |0 |"T1E1 input CRC error (CRC)" |
|....|........|.......|.......|................................................|
|30 |minor |enable |0 |"T1E1 input Bipolar Violation (BPV)" |
|....|........|.......|.......|................................................|
|31 |minor |enable |0 |"T1E1 input frequency error" |