286 TimeProvider 2300/2700 User’s Guide 098-00564-000 Revision A3 – July, 2013
Appendix A System Messages
System Notification Messages
1. The excessive traffic alarm is set if the count of Ethernet packets received in one second exceeds a
threshold. All traffic received by the TP2700 Ethernet ports is counted, such as ARP, ICMP, IGMP, PTP
unicast signaling, multicast, and PTP management messages.
Threshold:
1200 packets/sec for each port
System log time has
been updated
154 Event Yes System log time has been
updated
n/a
Not supported at this time
n/a
System reboot 155 Event Yes System reboot
n/a
No action required
n/a
Table A-2. Secondary Index Descriptions for System Notification Messages
Event
ID
Description
Secondary
Index
Secondary Index
Description
001 Entered time/frequency warm-up
state
0 - 1 0=time
1=freq
002 Entered time/frequency free-run
state
0 - 1 0=time
1=freq
003 Entered time/frequency fast-track
state
0 - 1 0=time
1=freq
004 Entered time/frequency
normal-track state
0 - 1 0=time
1=freq
005 Entered time/frequency bridging
state
0 - 1
0=time
1=freq
006 Entered time/frequency holdover
state
0 - 1 0=time
1=freq
007 Entered time/frequency extended
holdover state
0 - 1 0=time
1=freq
008 Entered time/frequency holdover
recovery state
0 - 1
0=time
1=freq
Table A-1. System Notification Messages (Continued)
Description
Event
ID
Msg
Level
Trans-
itory
MsgText Corrective Action