098-00564-000 Revision A3 – July, 2013 TimeProvider 2300/2700 User’s Guide 163
Chapter 3
TimeProvider 2300/2700 CLI Command Set
Currently Selected Timing reference : GNSS
Packet Service Eth1 mode : CLIENT PORT
Packet Service Eth2 mode : MASTER PORT
Eth1 Active connector interface : R1-RJ45
Eth2 Active connector interface : R2-RJ45
Frequency Offset (MDEV ppb) : 0.15
Phase Offset (TDEV ns) : 63.61
Active Alarms : 2
System Frequency PQL : 1
Level : User, Config, and Admin
Table 3-6. Clock Status
TP 2300/2700
Clock Status
Description
Possible Next
State
Conditions Required
for Next Transition
State
Warmup The unit is warming up. This is
the first clock state following
power-up or reboot.
Typical Warm-up time is:
Quartz: 6 minutes
Rubidium: 9 minutes
Note: Warm-up times may vary
based on environmental
conditions and other factors.
Freerun Warm-up complete
Freerun The unit is operating without
an input reference, but is
ready to use one. This state
will persist if no qualifiable
input reference is provided.
While in this state, the stability
of the clock output is tied to
the internal reference
oscillator.
Fast-track Input becomes qualified