162 TimeProvider 2300/2700 User’s Guide 098-00564-000 Revision A3 – July, 2013
Chapter 3
TimeProvider 2300/2700 CLI Command Set
show status
Use this command to display the following system status information:
Assigned System Name
System Date And Time
System Uptime
Time Traceable
Clock Frequency Status
Clock Timing Status
Frequency State Duration in Minutes
Time State Duration in Minutes
Currently Selected Timing reference Input
Currently Selected Frequency reference Input
Packet Service Eth1 mode: PTP client
Packet Service Eth2 mode: PTP Master
Eth1 active connector interface: RJ45
Eth2 active connector interface: SFP
Frequency Offset
Phase Offset Value (Valid in fast-lock and normal states)
Active Alarms #
System Frequency PQL
Command Syntax:
show status
Example:
TP2700> show status
Response:
System name : Timeprovider
System Date and time : 2013-05-09,15:29:31
Time Traceable : YES
System uptime (sec) : 1976
Clock Frequency Status : NORMAL
Clock Time Status : NORMAL
Frequency State Duration (min) : 10
Time State Duration (min) : 10
Currently Selected Frequency reference : GNSS