098-00564-000 Revision A3 – July, 2013 TimeProvider 2300/2700 User’s Guide 227
Chapter 4 Provisioning
Provisioning Alarms
3. Type set ref frequency state t1e1 enable and press Enter.
4. Type
set clock date-time <value> and press Enter. Enter the value in
format yyyy-mm-dd,hh:mm:ss.
Provisioning Alarms
This section describes the commands used to provision and manage alarms in the
TimeProvider 2300/2700. The user can provision the alarms to be enabled or
disabled and set thresholds to turn the alarms on and off. For a list of all alarms, see
Appendix A, System Messages.
Software commands allow you to perform the following:
Provision the severity level
Provision the alarm (enable or disable)
Show current alarm settings
Show current alarms
Display alarm status
Alarms are also indicated by an LED on the front panel.
Note: Disabling an input port will clear all alarms and events related
to the port.