098-00564-000 Revision A3 – July, 2013 TimeProvider 2300/2700 User’s Guide 235
Chapter 4 Provisioning
Testing TP 2300/2700 Provisioning
Adding and Removing SNMP v3 Trap Users
Use the set snmp add trapuser command to add a v3 trap user. Use the set
snmp delete trapuser
command to remove an existing v3 trap user. The TP
2300/2700 will support a maximum of 3 v3 trap users.
Example - Add Trap User
To add a trap user named “test12” with a security level of “priv”, with the
20-character MD5 authentication key “123456789ABCDEFGHIJK” and
16-character DES privacy key “ABCDEFG123456789”:
1. Type
set snmp add trapuser test12 securlvl priv then press Enter.
2. Enter
MD5 at the authentication protocol prompt.
3. Enter
123456789ABCDEFGHIJK at the authentication key prompt.
4. Enter
DES at the privacy protocol prompt.
5. Enter
ABCDEFG123456789 at the privacy key prompt.
Example - Remove Trap User
To remove an existing trapuser named “dave123”, type
set snmp delete
trapuser dave123
then press Enter.
Testing TP 2300/2700 Provisioning
Perform the tests in this section to verify that the TP 2300/2700 is provisioned and
operating correctly.
LED Indications
The LEDS on the front panel of the TP 2300/2700 illuminate in the following way
when the TP 2300/2700 is installed and provisioned:
The Power LED should be green.
The PWR A and/or PWR B LEDs should be green.
(DC power versions of TP 2300/2700 only)
Note: In order to access trap information, a trap user must also
be added as a user. The same name, authentication protocol,
authentication key, privacy protocol, and privacy key must be
used for both the user and trap user.