098-00564-000 Revision A3 – July, 2013 TimeProvider 2300/2700 User’s Guide 231
Chapter 4 Provisioning
Provisioning for SNMP
Restoring Provisioning Data
Example 1
To change the current configuration to factory default while preserving user and IP
information, type
set configuration default and press Enter.
Example 2
To change the current configuration to the factory default, type set configuration
factory
and press Enter.
Provisioning for SNMP
The Simple Network Management Protocol (SNMP) is an application layer protocol
that allows you to manage network devices. SNMP is based on a client-server
query-response mode that requires an Ethernet connection. A manager application
(software installed on a computer) is the client generating the queries, and an agent
(software on the TimeProvider 2300/2700) is the server generating responses. The
TimeProvider 2300/2700 SNMP supports traps and the MIB-II system MIB.
TimeProvider 2300/2700 supports SNMPv2c and SNMPv3. SNMPv3 provides
additional security features not available in SNMPv2c. In addition to the functions of
SNMPv2c, SNMPv3 allows user and trapuser levels that are based on
authentication and privacy settings. The authentication algorithm is either
HMAC-SHA-1-96 or MD5, with a 20-character key. The privacy settings are based
on either the CBC-DES or AES encryption standard, with a 16-character key. All
keys are uppercase.
Port 161 is the port of standard SNMP interactive communications and port 162 is
the trap port.
SNMP functionality is provisioned on the TP 2300/2700 using the CLI command
set snmp” (see Figure 4-26).
Each alarm trap OID from the TP 2300/2700 represents a unique alarm.
Note: The system will automatically reboot after receiving either
the "
set configuration default" or "set configuration
factory
" commands
Notes: Setting the configuration to default will not overwrite the
user login information or the IP address of MGMT port. Setting the
configuration to factory will overwrite the user login information and
return the IP address of MGMT port to the factory set address.