098-00564-000 Revision A3 – July, 2013 TimeProvider 2300/2700 User’s Guide 245
Chapter 4 Provisioning
Testing TP 2300/2700 Provisioning
Time Scale : PTP
Time Source : GPS
Time Traceable : true
Frequency Traceable : true
Steps Removed : 1
3. Use the procedure Verifying the Reference, on page 239 to check the reference
configuration and status.
Verifying SyncE Functionality
Input
1. Type
show synce config all and press Enter.
SyncE Config:
----------------------------
|Port |State |QL State|
|------|----------|--------|
|eth1 |enable |enable |
|......|..........|........|
|eth2 |enable |enable |
----------------------------
2. Type show synce status all and press Enter.
– Verify that the Ethernet Mode is “synchronous”.
– Verify that the RxSSM value for ETH1 port is consistent with the quality
needed for your network.
-------------------------------------------------------
|Port |Direction |Ethernet Mode |RxSSM |TxSSM |
|--------|----------|---------------|--------|--------|
|eth1 |input |synchronous |0x02 |0x0f |
|........|..........|...............|........|........|
|eth2 |output |synchronous |0xff |0x02 |
-------------------------------------------------------
3. Use the procedure Verifying the Reference, on page 239 to check the reference
configuration and status.
Output
1. Type
show synce config all and press Enter.
SyncE Config: