244 TimeProvider 2300/2700 User’s Guide 098-00564-000 Revision A3 – July, 2013
Chapter 4 Provisioning
Testing TP 2300/2700 Provisioning
PTP Announce Interval : 1
PTP Delay Interval : -6
PTP Clock Id : 00:b0:ae:ff:fe:03:46:05
PTP Domain : 0
PTP Announce Receipt Timeout : 3
PTP master-table:
------------------------------
|Index |address |
|-------|--------------------|
|1 |192.168.9.41 |
|.......|....................|
|2 |0.0.0.0 |
------------------------------
2. Type show ptp client status eth1 and press Enter.
– Verify that flow weights are non-zero values.
ETH1 PTP CLIENT STATUS:
Client Status : OK
Minimal Round Trip Delay(us) : 0.72
METRIC : FORWARD REVERSE
Flow Weight (%) : 47.78 52.22
Transient free out of 900s : 900 900
Transient free out of 3600s : 3600 3600
Percentile Clustering (%) : 100.0 100.0
Operational Min TDEV (ns) : 3.2 3.2
Operational MAFE (ppb) : 0.00 0.00
Min Cluster Width (ns) : 15000.0 7500.0
Mode width (ns) : 30000.0 15000.0
Packet Rate (pkts/s) : 64 64
Currently Used Master:
IP Address : 192.168.9.41
Clock ID : 00:b0:ae:ff:fe:03:46:69
Port Number : 2
Clock Class : 6
Clock Accuracy : within 100 ns