098-00564-000 Revision A3 – July, 2013 TimeProvider 2300/2700 User’s Guide 243
Chapter 4 Provisioning
Testing TP 2300/2700 Provisioning
PTP Sync Limit : -7
PTP Announce Limit : -4
PTP Delay Limit : -7
PTP Clock Id : 00:b0:ae:ff:fe:03:46:05
PTP Priority 1 : 128
PTP Priority 2 : 128
PTP Domain : 0
PTP Timescale : auto
4. Type show ptp master status eth2 and press Enter.
Verify that the port is enabled.
Verify that the profile matches the desired setting.
If clients are configured to use this master, verify that number of attached
clients matches the number of clients configured.
ETH2 PTP MASTER STATUS :
Port enabled : yes
Clock Id : 00:b0:ae:ff:fe:03:46:05
Port Number : 2
Profile : telecom-2008
Port state : master
Clock class : 6
Clock accuracy : within 100 ns
Timescale : ptp
Maximum allowed clients : 64
Number of attached clients : 8
Client load : 12%
Verifying PTP Input Client Functionality
1. Type show ptp client config eth1 telecom-2008 and press Enter.
Verify that the PTP State is “enable”.
Verify that the PTP settings match the desired values.
Verify that the IP address for the master is set to the correct value.
ETH1 PTP CLIENT CONFIGURATION WITH PROFILE TELECOM-2008:
PTP State : enable
PTP TTL : 64
PTP DSCP : 0
PTP Unicast Negotiation : enable
PTP Unicast Lease Duration : 300
PTP Sync Interval : -6