76 TimeProvider 2300/2700 User’s Guide 098-00564-000 Revision A3 – July, 2013
Chapter 3
TimeProvider 2300/2700 CLI Command Set
show eia-232
This command displays the serial port’s operating parameters: baud rate, parity,
word length, and stop bits.
Command Syntax:
show eia-232
Example:
TP2700> show eia-232
Response:
Baud rate : 57600
Data length : 8
Stop bit : 1
Parity : 0
Flow control : none
Remarks: The system's serial interface is fixed at 57.6K, 8, 1, 0; there is no
handshaking. There is no associated Set command.
Level : User, Config, and Admin