EasyManuals Logo

Symmetricom TimeProvider 2700 User Manual

Symmetricom TimeProvider 2700
338 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #106 background imageLoading...
Page #106 background image
106 TimeProvider 2300/2700 User’s Guide 098-00564-000 Revision A3 – July, 2013
Chapter 3
TimeProvider 2300/2700 CLI Command Set
show log-config
Use this command to display the configuration for log size and remote-syslog.
Command Syntax:
To show configuration of the log size:
show log-config size {alarm-event | command | security}
To show configuration of the remote-syslog:
show log-config remote-syslog
Example 1:
To display size of the alarm log:
TP2700> show log-config size alarm-event
Response 1:
Log size of alarm-event log is : 100 kilobytes
Example 2:
To display the configuration of the remote-syslog:
TP2700> show log-config remote-syslog
Response 2:
Remote-syslog config:
State : disable
Remote Address : 0.0.0.0
Level : User, Config, and Admin
set log-config
Use this command to provision the specified log file buffer size, the maximum
number of kilobytes to be stored in the file before it is rotated, and to configure a
remote syslog server to receive log messages from the TimeProvider 2700.
Command Syntax:
To configure the size of the log:

Table of Contents