248 TimeProvider 2300/2700 User’s Guide 098-00564-000 Revision A3 – July, 2013
Chapter 4 Provisioning
Testing TP 2300/2700 Provisioning
2. Type show output status t1e1 and press Enter.
Verify that the IO Status shows the desired signal format and “output”.
Verify that the Port Status is “on”.
------------------------------------
| Port | io status | port status |
|------|-----------|---------------|
| t1e1 | e1 output | on |
|..................................|
Verifying TOD Functionality
1. Type show port-control and press Enter.
Verify that the State for the TOD port is “enable”.
Verify that the Signal/Format is the desired type.
--------------------------------------------
|# |Port |State |IO dir |Signal/Format|
|---|-------|--------|-------|-------------|
|1 |t1e1 |enable |output |t1 |
|...|.......|........|.......|.............|
|2 |pps10m |enable |output |10MHz |
|...|.......|........|.......|.............|
|3 |tod |enable |output |cisco |
--------------------------------------------
2. Type show output status tod and press Enter.
Verify that the State for the TOD port is “enable”.
Verify that the Signal/Format is the desired type.
TOD CISCO output message
*,A,56415,13/05/02,03:52:17,000.0,0,37N22.716,121W55.581,+00
14
or
TOD China Mobile output message