098-00564-000 Revision A3 – July, 2013 TimeProvider 2300/2700 User’s Guide 69
Chapter 3
TimeProvider 2300/2700 CLI Command Set
2 - Critical
3 - Major
4 - Minor
5 - Event
To provision the reporting delay of the specified Alarm number in seconds:
set alarm-config delay {alarm [0 to 300] | all}[0 to 500000]
Example 1:
To Disable alarm #31
TP2700> set alarm-config state alarm 31 disable
Example 2:
To set the level of alarm #31 to Error - major (3):
TP2700> set alarm-config level alarm 31 3
Example 3:
To set the reporting delay of alarm #31 to 5 seconds:
TP2700> set alarm-config delay alarm 31 5
Remarks: The severity level and delay of transitory events cannot be changed.
Level : Config and Admin
Note: Use “show alarm-config” command to view the max-alarm-id of
current TP 2300/2700 release.