098-00564-000 Revision A3 – July, 2013 TimeProvider 2300/2700 User’s Guide 155
Chapter 3
TimeProvider 2300/2700 CLI Command Set
To set the config-PQL value to 4 for a GNSS time reference input:
set ref time config-pql gnss 4
Example 3:
To set the priority value to 6 for a SyncE frequency reference input:
set ref frequency priority synce 6
Example 4:
To set the config-PQL value to 5 for a T1/E1 frequency reference input:
set ref frequency config-pql t1e1 5
Example 5:
To configure the PTP reference inputs to use either the user-provisioned PQL value:
set ref use-config-pql ptp enable
Example 6:
To set the unit for reference selection based on Priority values
set ref criteria priority
Example 7:
To set the reference switching to auto-return mode:
TP2700> set ref switch-mode auto-return
Defaults:
use-config pql = enable
reference switch = auto-return (for both time and frequency)
Reference Priority pql
-------------------------------------------
GNSS 1 1
PTP 2 3
SYNCE 3 3
T1E1 4 3